![FANOX SIL B Скачать руководство пользователя страница 115](http://html1.mh-extra.com/html/fanox/sil-b/sil-b_user-manual_4588707115.webp)
Rev.23
115/311
In the following example:
•
input 1 is assigned to contact a of the circuit breaker.
•
input 2 is assigned to contact b of the circuit breaker.
•
input 3 is assigned to the function 50P block.
•
input 4 is assigned to the function 50N/G block.
•
In addition, it is understood that there is an additional protection, which starts up 79 and
assigns input 5 to said start. As well as bouncing the trip, this input allows the oscillography
to start up.
•
A key is provided (input 6), which allows the 79 to be locked.
•
Similarly, this protection starts up the circuit breaker fault with input 7
•
and finally, the active table is controlled with input 8
•
The 79 permission function is not assigned to anything in particular, as a synchronizer is not
necessary for closure. However, in this case it is best to prohibit the wait time of the recloser.
Logical inputs
Inp1
Inp2 Inp3
Inp4
Inp5
Inp6
Inp7
Inp8
Not configured
Input 52 a
X
Input 52 b
X
50P block input
X
50N/G block input
X
External trip input
X
Fault init Input
X
79 init input
X
Permission 79 input
Locking 79 level input
X
Input-1 Table Active
Input-2 Table Active
X
Locking 79 input pulse
Unlock 79 pulse input
50BF init input
X
Содержание SIL B
Страница 1: ...EN_FANOXTD_MANU_SIL_Feeder_SILB_R023 Docx USER S MANUAL SIL B Feeder Relay...
Страница 8: ...www fanox com Rev 23 8 311 2 DIMENSIONS AND CONNECTION DIAGRAMS 2 1 Equipment front view...
Страница 9: ...www fanox com Rev 23 9 311 2 2 Equipment dimensions...
Страница 10: ...www fanox com Rev 23 10 311...
Страница 11: ...www fanox com Rev 23 11 311 2 3 Cut out pattern CUT OUT PATTERN...
Страница 12: ...www fanox com Rev 23 12 311 2 4 Connection diagrams Analog connections...
Страница 13: ...www fanox com Rev 23 13 311...
Страница 14: ...www fanox com Rev 23 14 311 Digital connections Outputs and Trip circuit supervision...
Страница 15: ...www fanox com Rev 23 15 311 2 5 Terminals IEC 61850 or DNP3 0 protocols...
Страница 17: ...www fanox com Rev 23 17 311 IEC 60870 5 103 protocol...
Страница 25: ...www fanox com Rev 23 25 311 3 3 Functional diagram...
Страница 28: ...www fanox com Rev 23 28 311 3 5 1 SIL B 1 CHARGE CURVE 3 5 2 SIL B 5 CHARGE CURVE...
Страница 38: ...www fanox com Rev 23 38 311 4 6 4 Thermal protection curves This is the thermal curve for 3 minutes...
Страница 91: ...www fanox com Rev 23 91 311...
Страница 140: ...www fanox com Rev 23 140 311...
Страница 194: ...www fanox com Rev 23 194 311 Polarization V 35 0 V C Operating Angle 180 C Halfcone Angle 3 C...
Страница 307: ...www fanox com Rev 23 307 311 50BF init Fault init 79 Closure permission 52 closure permission...
Страница 308: ...www fanox com Rev 23 308 311 12 8 LED s configuration LEDs Blinking Latch Negate d LED On LED 1 LED 2 LED 3 LED 4 LED 5...
Страница 310: ...www fanox com Rev 23 310 311 NOTES...
Страница 311: ...www fanox com Rev 23 311 311...