67N1 block permission: yes/no
67N2 block permission: yes/no
Phase blocking time: 0 to 300s (pass 0,01 s)
Neutral blocking time: 0 to 300s (pass 0,01 s)
Phase block signaling time: 0 to 300s (pass 0,01 s)
Neutral block signaling time: 0 to 300s (pass 0,01 s)
Oscillography
16 records per cycle
The beginning of the oscillography is configurable
2 register:3 cycle previous to the fault and 30 after fault
4 inputs configurables
The same voltage as auxiliary power supply
4 outputs configurables
250 Vac – 8 A
30 Vdc – 5 A
Resistive load (cos
φ
= 1)
Frequency
50/60Hz
Current measure
True RMS
Sampling: 16 samples/cycle
Accuracy of ±2% in a band of 20% over the rated current and 5% for the rest of
measurement range
Communications
RS232 port: Modbus RTU
RS485 port: Modbus RTU
Auxiliary power supply
110-230 Vac / 90-300 Vdc ±20%
24-48 Vdc ±20%
Battery supply
With KITCOM adapter DB9
Environment
Operating temperature: -10 to 60ºC
Storage temperature: -20 to 70 ºC
Humidity: 95%
Transformers
Power supply and measurement CT /5 or /1
Mechanical features
Metallic box
Panel Mounting
1/2 Rack – 4 U
Depth: 74,6 mm
IP-52
Содержание SIA D
Страница 1: ...www fanox com SIA D_Rev 07 1 117 ISO 9001 2008 USER MANUAL SIA D Overcurrent relay...
Страница 36: ...www fanox com SIA D_Rev 07 36 117 ISO 9001 2008...
Страница 37: ...www fanox com SIA D_Rev 07 37 117 ISO 9001 2008...
Страница 38: ...www fanox com SIA D_Rev 07 38 117 ISO 9001 2008...
Страница 58: ...www fanox com SIA D_Rev 07 58 117 ISO 9001 2008...
Страница 60: ...www fanox com SIA D_Rev 07 60 117 ISO 9001 2008...
Страница 116: ...www fanox com SIA D_Rev 07 116 117 ISO 9001 2008 10 8 NOTES...