FTP3000 Series Programmable DC Power Supply Operation Manual
____________________________________________________________________________
- 32 -
4.
Press
to validate the input;
5.
Press
to start running sequence test output. The screen will display the current sequence file,
step number and cycle times. “STEP” stands for sequence current step, “Cycle” shows sequence file have run for how
many cycle times.
SEQ output function can simulate complex waveforms, such as below waveform:
Figure 3-19 Sequence Output Waveform
3.16 Constant Power Output (CP) Setting
FTP3000 series power supply supports constant power output function. After the output is turned on, the power
supply continuously adjusts the output voltage or output current to keep the output power constant. If the load
exceeds the regulation range of the power supply, the output will remain at the maximum set value.
-----------------------------------------------------------------------------------------------------------------------
CP output function is mainly used for loads with a response speed faster than 10ms.
-----------------------------------------------------------------------------------------------------------------------
Figure 3-20 CP Output Waveform
Operation procedures: