____________________________________________________________________________
- 19 -
3.2.2 Edit Menu
Press
to enter into main menu, then select “Edit” and press “Enter” to pop up
sub menu as below:
Table 3-2 Edit Menu Layout
Edit
Sequence
Select sequence file number, range 1~10
Back
Exit
3.2.3 About Menu
Press
to enter main menu, then select “About” and press “Enter” to pop up sub
menu such as HMI, MAIN, COMM program version information etc..
3.3 VI (CV/CC) Output Function
Press
or
function key, the power supply enters into CV/CC output mode, display
as below:
Figure 3-1 VI Output Function Interface
Setting output voltage
1.
Press
to enter into VI output page, the cursor is in “V-Set”, press
to go to edit state.
2. Rotate the rotary knob to adjust the value, or press number key and decimal point key to enter voltage value.
3. Press
to validate the input.
Setting output current
1.
Press
to enter into VI output interface, the cursor is in “I-Set”, press
to go to edit state.
2. Rotate the rotary knob to adjust the value, or press number key and decimal point key to enter current value.
3. Press
to validate the input.