FTP3000 Series Programmable DC Power Supply Operation Manual
____________________________________________________________________________
- 8 -
Analog output
Output voltage
0
~
100%F.S. corresponds to 0
~
5V.
Voltage accuracy
0.5%F.S.
Current accuracy
0.5%F.S.
Line regulation
Voltage
0.01%+0.01%F.S.
Current
0.02%+0.01%F.S.
Load regulation
Voltage
0.01%+0.05%F.S.
Current
0.02%+0.1%F.S.
Voltage measurement
Resolution
16Bits
Accuracy
0.1%+0.1%F.S.
Current measurement
Resolution
16Bits
Accuracy
0.1%+0.2%F.S.
Output noise & ripple
Ripple Vpp
40mV
60mV
80mV
150mV
300mV
Ripple Vrms
10mV
20mV
20mV
30mV
60mV
Slew rate
Voltage
5V/ms(max)
Current
2A/ms(max)
OVP setting
Range
0
~
110%F.S.
Accuracy
1%F.S.
Transient response
Typical 1ms, voltage recover to the designed accuracy after a 50% change of load
Efficiency
0.9(Typical)
Communication
RS232, LAN
INPUT
190VAC
~
265VAC, 47Hz
~
63Hz, PF: 0.99(Typical)
Working temp
0
℃
~
40
℃
Storage temp
-20
℃
~
70
℃
Altitude
<
2000m
Size
215 (W)×88(H)×452.5(D)mm
Weight
7kg