FTP9000 Series Programmable DC Power Supply Operation Manual
____________________________________________________________________________
- 42 -
Set
System
Edit
About
M_or_S
Master
S.NUM
1
MS_CTRL
OFF
Figure 3-20 Master-Slave Parallel Set
1. Press
to enter main menu interface;
2. Select “Set” >> “Parallel”, then press
to display master-salve parallel set page;
3. “M_or_S” item set as “Master”;
4. “S.NUM” item set as the actual number of slave power supplies;
5. “
MS_CTRL
” item as as “ON”.
Press
to return to main page after completing the parallel parameter setting. The master power supply
specifications will be updated.
3.15.3 Master-slave parallel function operations
Simply operate the master unit to control the whole group if you have configured the master-slave parallel
correctly. The relative protections are still in effect once parallel function is turned on. The system will
automatically turn off all power outputs if one unit in the group is protected. The corresponding slave unit
displays the specific fault information, and the master unit displays the master fault information and the fault slave
code, as shown in the figure below: