FTP9000 Series Programmable DC Power Supply Operation Manual
____________________________________________________________________________
- 40 -
Voltage A
Set voltage for A, range: 0 - Max output voltage
Voltage B
Set voltage for B, range: 0 - Max output voltage
Voltage C
Set voltage for C, range: 0 - Max output voltage
V
slew rate
- AB
Set voltage slew rate from A to B, range: 0.0006V/s to
6000V/s, default value 50% max slew rate
V
slew rate
- BC
Set voltage slew rate from B to C, range: 0.0006V/s to
6000V/s, default value 50% max slew rate
I_Set
Set output current, range: 0 - Max output current
P_Set
Set output power, range: 0 - Max output power
V
Voltage A
Voltage C
Voltage B
t
Figure 3-18 RAMP Function Parameter Set
3.15 Master-slave Parallel
3.15.1 Master-slave parallel connection
FTP9000 series power supplies provide a master-slave parallel mode, so that users can achieve greater output
power by paralleling same models. The user uses proper wires to connect the "Share" interface in the rear panel,
the "RS485" parallel communication interface in the “PRO-INT” port, and the output positive and negative poles
according to "Figure 3-19 Master-Slave Parallel Connection", and then make corresponding configuration for the
power supplies to realize the master-slave parallel function, operating the whole group is as simple as operating a
stand-alone power supply.