Analog programming control speed is 1000 points per second, external 0 ~ 5V DC voltage corresponds to 0 ~
100%F.S. output voltage, current, power.
Figure 3-7 Input Programming Signal And Output Relation
Operation:
1. Press
to enter the main menu.
2. Select “Set” >> “EXT Prog” and press
to enter external programming page as shown below:
Set
System
Edit
About
APG_V
OFF
APG_I
OFF
APG_P
OFF
EXT-S
Trigger
Figure 3-8 External Programming Set
3. Select APG_V, APG_I, APG_P for performing voltage programming, current programming or power
programming turn on/off operations respectively, the status prompt area will prompt “E-VIP” symbol if any of
these three programming selections is turned on.
4. Press
to turn on output.
----------------------------------------------------------------------------------------------------------------------------
1. Altering of “External Programming Set” is allowed only when the output is turned off.
2. The external signal controls the output voltage/current/power on the condition that
corresponds voltage/current/power programming is turned on, otherwise the power supply
output can still be controlled by the front panel or remote communication.
----------------------------------------------------------------------------------------------------------------------------