FTP9000 series power supply allows for output voltage ramp-up and ramp-down according to the set slew rate.
Operation:
1. Press
to enter test modes selection interface;
2. Use “Rotary”
knob to select “RAMP”, press
, the screen displays as below:
80V/510A/15000W
RAMP
1/3
0.0000
V
0.0000
A
0.000
w
Voltage A
0.000 V
Voltage B
0.000 V
Voltage C
0.000 V
Off
80V/510A/15000W
RAMP
2/3
0.0000
V
0.0000
A
0.000
w
V
slew rate
- AB
0.000 V/s
V
slew rate
- BC
0.000 V/s
I_Set
0.000 A
Off
80V/510A/15000W
RAMP
3/3
0.0000
V
0.0000
A
0.000
w
P_Set
0.000 W
Off
Figure 3-17 RAMP Function Parameter Set
3. Set the corresponding parameters, you can refer to “Table 3-6 RAMP Function Parameter Explanation” ;
4. Press
to turn on voltage ramp output.
Table 3-6 RAMP Function Parameter Explanation
Parameter
Explanation