MCS- 34/92
Digital Brushless AC servo drive system - Ref.0707
INSTALLATION
General considerations
At the motor
Remove the anti-corrosion paint of the shaft before mounting them on to the machine.
The motor may be mounted as described in the first chapter (B5, V1 and V3).
Watch for the ambient conditions mentioned in the section on general characteristics
and also:
Mount it somewhere that is dry, clean and accessible for maintenance.
It must be easily cooled.
Avoid corrosive or flammable environments.
Guard the motor with a cover if it is exposed to splashes.
Use flexible coupling for direct transmission.
Avoid radial and axial loads on the motor shaft.
At the Drive
The module must be installed in an electrical cabinet that is clean, dry, free of dust, oil
and other pollutants.
Never install it exposing it to flammable gases. Avoid excessive heat and humidity. The
ambient temperature must never exceed 45 °C (113 °F). Install the modules vertically,
avoid vibrations and respect the gaps to allow air flow.
See figure.
Remember that
the degree of protection is IP64.
WARNING:
DO NOT hit the shaft when installing transmission pulleys or
gears!
Use some tool that is supported in the threaded
hole on the shaft to insert the pulley or the gear.
Remember that
the degree of protection is IP20.