MCS- 70/92
Digital Brushless AC servo drive system - Ref.0707
Function:
Variable containing the parameters that are readjusted by the
drive when it issues the error E.502 (incompatible
parameters). The parameters are listed by their bus identifier
(the WinDDSSetup shows the parameter names directly).
Valid values:
Any parameter bus identifier.
Default value:
0.
Function:
This variable contains the number of the node assigned to
the drive for communication.
Valid values:
0, ..., 127.
Default value:
0.
R group. Rotor sensor
Function:
Compensation (proportional gain mode) of the amplitude of
the sine/cosine signal that goes from the motor feedback to
the drive. Entering 4096 is the same as multiplying by 1. To
assign a gain of 1.5 to the sine signal, set RP1 to 6144 (=
4096 x 1.5).
Valid values:
0 (0 %) ... 8192 (200 %).
Default value:
4096 (100 %).
QV22 FAGOR, RO
IDNListOfInvalidOperationData
QV96 USER, RW
SlaveArrangement
Value
ModBus protocol
0
Number Nr 0 (not commonly used )
1, ..., 127
Node Nr assigned to the unit in a bus type
communication.
RP1
FAGOR, RW
FeedbackSineGain
RP2
FAGOR, RW
FeedbackCosineGain