MCS- 76/92
Digital Brushless AC servo drive system - Ref.0707
Function:
In emergency stop. If the bus voltage drops or there is a power
outage for the unit in the acceleration, deceleration or
constant power mode, the drive will get into the dynamic
braking sequence. It stops with the emergency ramp until its
speed is zero as long as the mechanical energy stored in the
motor allows it. Therefore, it limits the command acceleration
for stopping the motor. If anytime during the sequence, the
Drive Enable is interrupted, the motor will turn by inertia.
SP65 = 0 cancels this limiting effect.
Valid values:
0.0, ..., 400.0 (rev/min)/ms.
Default value:
0.
Function:
Determine the value of the deceleration ramp applied to the
velocity command. Setting this parameter with a 0 value
means that no ramps will be applied.
Valid values:
0.0, ..., 400.0 (rev/min)/ms.
Default value:
0.
Function:
Velocity command after the SP45 selector.
Valid values:
- 6000, ..., 6000 rev/min.
SP65 BASIC, RW
EmergencyAcceleration
SP66 BASIC, RW
VelocityDecelerationTime
SV1
BASIC, RW
VelocityCommand
Power Off
Motor
Speed
Power Off
Motor Free
Drive
Enable
Speed
Enable
Motor
Speed
Drive
Enable
Speed
Enable
SP60
SP66
SP60
SV6
SP66