BCSD-110/116
Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
Parameter
No.
Description
Setting
Validation
Function and Meaning
Pn700
Hex
After restart
Pn700.0 MODBUS communication baud rate
[0] 4800 bps
[1] 9600 bps
[2] 19200 bps
Pn700.1 MODBUS protocol selection
[0] 7, N, 2 (MODBUS,ASCII)
[1] 7, E, 1 (MODBUS,ASCII)
[2] 7, O, 1 (MODBUS,ASCII)
[3] 8, N, 2 (MODBUS,ASCII)
[4] 8, E, 1 (MODBUS,ASCII)
[5] 8, O, 1 (MODBUS,ASCII)
[6] 8, N, 2 (MODBUS,RTU)
[7] 8, E, 1 (MODBUS,RTU)
[8] 8, O, 1 (MODBUS,RTU)
Pn700.2 Communication protocol selection
[0] No protocol SCI communication
[1] MODBUS SCI communication
Pn700.3 Reserved
Pn701
MODBUS Axis
address
After restart
Axis address of MODBUS protocol communication
Pn702
Reserved
Pn703
CAN
communication
speed
After restart
Pn703.0 CAN communication baud rate
[0]-[3] Reserved
[4] 500 Kbps, only when the CAN cable length is more than
20 m.
[5] 1 Mbps, this is the suggested configuration, and the CAN
cable maximum length is limited to 20 m.
Pn704
CAN
communication
contact
After restart
CAN Axis address of communication
Pn840
Hex
After restart
Pn840.0 Encoder model selection
[0]-[2] Reserved (For factory using)
[3] 17-bit absolute encoder
[4] 17-bit incremental encoder
Pn840.1 Reserved (For factory using)
Pn840.2 Reserved (For factory using)
Pn840.3 Reserved (For factory using)
Содержание BCSD Series
Страница 1: ...SYSTEM BCSD User manual Ref 1809...
Страница 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Страница 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Страница 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Страница 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Страница 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Страница 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Страница 117: ......