Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
BCSD-73/116
4.6.3. Setting Online Autotuning
Related parameters:
4.6.4. Machine Rigidity Setting for Online Autotuning
There are 16 machine rigidity settings for online autotuning, When the machine rigidity setting is selected,
the servo gains (speed loop gain, speed loop integral time constant) are determined automatically. The
factory setting for the machine rigidity setting is 5.
Parameter
No.
Name
Unit
Setting
Range
Factory
Setting
Setting
Invalidation
Pn100
Online autotuning setting
0: Manual gain adjustment
1, 2, 3 = Normal mode; 4, 5, 6 = Vertical load
1, 4 = Load inertia without variation;
2, 5 = Load inertia with little variation;
3, 6 = Load inertia with great variation
—
0 ~ 6
1
After restart
Pn101
Machine rigidity setting
—
0 ~ 15
5
Immediately
Pn128
Speed gain acceleration relationship
during online autotuning
If the setting is greater, the servo gain will
increase.
—
0 ~ 3
3
Immediately
Machine Rigidity Setting
Speed Loop Gain [rad/s]
Pn102
Speed Loop Integral Time
Constant [0.1 ms]
Pn103
0
40
800
1
60
600
2
80
450
3
100
400
4
120
300
5
160
200
6
260
140
7
320
110
8
400
90
9
480
80
10
560
70
11
640
60
12
720
55
13
840
50
14
1000
40
15
1200
30
Содержание BCSD Series
Страница 1: ...SYSTEM BCSD User manual Ref 1809...
Страница 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Страница 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Страница 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Страница 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Страница 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Страница 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Страница 117: ......