BCSD-50/116
Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
The servomotor can be operated using only the panel operator without reference from the host controller.
Pay attention that the Forward Run Prohibited (P-OT) and Reverse Run Prohibited (N-OT) signals are
invalid during JOG mode operation.
4.1.2. Trial Operation for Servomotor without Load from Host Reference
Check that the servomotor move reference or I/O signals are correctly set from the host controller to the
servodrive.
Also check the wiring and polarity between the host controller and servodrive, and the servodrive operation
setting are correct. This is final check before connecting the servomotor to the machine.
1. Servo ON Command from the Host.
The following circuits are required: External input signal circuit or equivalent.
Pn305
JOG Speed
Speed
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 ~ 6000
rpm
500
immediately
Set the utility function Fn002 (JOG Mode Operation) to the reference value of servomotor speed.
Содержание BCSD Series
Страница 1: ...SYSTEM BCSD User manual Ref 1809...
Страница 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Страница 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Страница 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Страница 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Страница 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Страница 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Страница 117: ......