Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
BCSD-83/116
5.1.6. Operation in Monitor Mode
The monitor mode allows the reference values input into the servodrive, I/O signal status, and servodrive
internal status to be monitored.
• Using the Monitor Mode
The example below shows how to display 1500, the contents of monitor number Un001.
• List of Monitor Modes.
Contents of Monitor Mode Display.
1. Press MODE key to select the monitor mode.
2. Press the INC or DEC key to select the monitor number to display.
3. Press the ENTER key to display the data for the monitor number selected at step 2.
4. Press the ENTER key once more to return to the monitor number display.
Monitor Number
Monitor Display
Un000
Actual servomotor speed Unit: rpm
Un001
Input speed reference Unit: rpm
Un002
Reserved
Un003
Internal torque reference Unit: %
(with respect to rated torque)
Un004
Number of encoder rotation angle pulses
Un005
Input signal monitor
Un006
Encoder signal monitor
Un007
Output signal monitor
Un008
Reserved
Un009
Reserved
Un010
Reserved
Un011
Reserved
Un012
Reserved
Un013
Reserved
Un014
Reserved
Un015
Load inertia percentage
Un016
Servomotor overload ratio
Содержание BCSD Series
Страница 1: ...SYSTEM BCSD User manual Ref 1809...
Страница 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Страница 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Страница 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Страница 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Страница 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Страница 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Страница 117: ......