BCSD-40/116
Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
3.2.2. I/O Signal Names and Functions
• Input Signals.
• Output Signals.
Control
Mode
Signal
Name
Pin
No.
Function
Speed
/S-ON
14
Servo ON: Turns the servomotor on.
P-OT
N-OT
16
17
Forward run prohibited
Reverse run prohibited
Overtravel prohibited:
Stops servomotor when OFF.
/ALM-RST
39
Alarm reset: Releases the servo alarm state.
DICOM
13
Control power supply input for I/O signals: Provide the +24 V DC power
supply.
VREF+
1
Speed reference input: ±10 V.
VREF-
2
Control
Mode
Signal
Name
Pin No.
Function
Speed
ALM+
7
Servo alarm:
Turns off when an error is detected.
ALM-
8
/S-RDY+
9
Servo ready:
ON if there is no servo alarm when the control/main circuit power
supply is turned ON.
/S-RDY-
10
PAO+
20
Phase-A signal
Converted two-phase pulse (phases A and B)
encoder output.
PAO-
21
PBO+
22
Phase-B signal
PBO-
23
PCO+
24
Phase-C signal
Zero-point pulse (Phase-C) signal.
PCO-
25
FG
Shell
Connected to frame ground if the shield wire of the
I/O signal cable is connected to the connector shell.
Reserved
-
4, 18, 19, 29,
35, 36, 37, 38,
43, 44, 45, 47,
49.
Not used.
Содержание BCSD Series
Страница 1: ...SYSTEM BCSD User manual Ref 1809...
Страница 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Страница 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Страница 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Страница 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Страница 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Страница 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Страница 117: ......