FR
50
MOD.
TENSIÓN
ALIMENTATION
SECTION
CÂBLE
FUSIBLE INT.
GENERALE
DISPOSITIF
DIFFÉRENTIEL
AG-061
230V 50-60Hz
2x1,5mm²+T
10A
300mA
PUISSANCE ÉLECTRIQUE 1,2 kW
PUISSANCE
GAZ
Kcal/h (Hi)
G30/G31/G20
10.325
BTU/h (Hi)
G30/G31/G20
40.975
kW (Hi)
G30/G31/G20
12
AG-101
230V 50-60Hz
2x1,5mm²+T
10A
300mA
PUISSANCE ÉLECTRIQUE 1,2 kW
PUISSANCE
GAZ
Kcal/h (Hi)
G30/G31/G20
15.488
BTU/h (Hi)
G30/G31/G20
61.460
kW (Hi)
G30/G31/G20
18
AG-201
230V 50-60Hz
2x1,5mm²+T
16A
300mA
PUISSANCE ÉLECTRIQUE 2,4 kW
PUISSANCE
GAZ
Kcal/h (Hi)
G30/G31/G20
30.975
BTU/h (Hi)
G30/G31/G20
122.920
kW (Hi)
G30/G31/G20
36
AG-102
230V 50-60Hz
2x1,5mm²+T
10A
300mA
PUISSANCE ÉLECTRIQUE 1,2 kW
PUISSANCE
GAZ
Kcal/h (Hi)
G30/G31/G20
30.115
BTU/h (Hi)
G30/G31/G20
119.505
kW (Hi)
G30/G31/G20
35
AG-202
230V 50-60Hz
2x1,5mm²+T
16A
300mA
PUISSANCE ÉLECTRIQUE 2,4 kW
PUISSANCE
GAZ
Kcal/h (Hi)
G30/G31/G20
55.928
BTU/h (Hi)
G30/G31/G20
221.938
kW (Hi)
G30/G31/G20
65
3.6
RACCORDEMENT DU GAZ (uniquement modèles gas)
Seul l'installateur de gaz local agréé peut effectuer le
branchement du gaz.
Il est indispensable de vérifier que les
tuyauteries d'alimentation en gaz ainsi que les
tuyauteries de connexion des systèmes de
mesure correspondants disposent du diamètre
indiqué.
Une fois l’appareil connecté, vérifier qu’il n’y a
pas de fuites, au moyen d’un détecteur de gaz
(spray, etc.). N’utiliser EN AUCUN CAS une
flamme pour vérifier les fuites.
CONSOMMATION MAXIMUM AVEC CHARGE THERMIQUE NOMINALE
TYPE DE
GAZ
PRESSION
NÉCESSAIRE
DE FLUIDITÉ
(MBAR)
PRESSION
MINIMALE
(MBAR)
PRESSION
MAXIMALE
(MBAR)
AG-061
AG-101
AG -
201
AG -
102
AG -
202
G-20
(M³/H)
20
17
25
1,270
1,905
3,809
3,704
6,878
G-30
(KG/H)
28-30
25
35
0,998
1,498
2,995
2,912
5,408
G-
31(KG/H)
37
42,5
57,5
0,984
1,476
2,951
2,869
5,329