Technical data
The following electrical input values apply to the filling level sensors:
Electrical
variable
TORRIX Ex
SC…
VISY-Stick
…
TORRIX Ex
…
TORRIX Ex
C…
TORRIX Ex
RS485…
TORRIX Ex
TAG…
TORRIX Ex
XT…
VISY-Stick
…
RS485
VISY-Stick
…
TLS
U
i
15 V
30 V
13 V
I
i
60 mA
100 mA / 200 mA
*
200 mA
P
i
100 mW
1 W
625 mW
C
i
<
10 nF
10 nF
20 nF
L
i
<
100 µH
20 µH
410 µH
Table 2: Electrical input data of intrinsic safe filling level sensors
The voltage for the type TORRIX Exd
… is
from 12 V to 50 V (U
m
= 253 V). The current is from 4 mA to 20 mA (Error
mode: 3.6 mA / 21.5 mA) respectively 10 mA when using RS-485. The supply voltage of the heater is 24 V ± 10 %
with a current of 160 mA.
When using the equipment in potentially explosive atmospheres please consult table 3 to table 6 for the maximum
temperatures depending on the equipment protection level and temperature class resp. surface temperature.
TORRIX Ex
SC…
/ VISY-Stick
…
For use in EPL Ga, EPL Ga/Gb and EPL Gb
Temperature class
T
a
T
F
T6
-
40 °C … +50 °C
-
40 °C … +
75 °C
T5
-
40 °C … +65 °C
-
40 °C … +
90 °C
T4
-
40 °C …
+85 °C
-
40 °C … +
125 °C
T3
-
40 °C … +
190 °C
T2
-
40 °C … +
285 °C
T1
-
40 °C … +
435 °C
For use in EPL Db
Maximum surface temperature
Ambient temperature T
a
dust layer ≤
5 mm
immersed in dust
X°C = T
a
+ 30 °C
X°C = 135 °C
-
40 °C … +85 °C
Table 3: Service temperatures of the filling level sensors in basic version (without interface board)
The equipment is suitable for dusts whose ignition temperature under a dust layer of 5 mm is greater than 190 °C
(glow temperature).
*
The permissible input current I
i
depends on the ambient temperature T
a