Indication and adjustment module
Page 18/
47
6
Indication and adjustment module
The TORRIX XTS is equipped with an indicating and adjustment module to display the meas-
ured values and for configuration.
The module for display and adjustment can be rotated to adapt to the conditions at the
installation site.
6.1
Rotation of the display and adjustment module
When delivered, the display and adjustment module is aligned with the lower edge towards
the probe tube. If this adjustment is to be changed, the housing cover with the viewing
window must first be removed. To do this, screw the locking screw of the cover into the
housing with a 3 mm Allen key. When the cover is removed, the display and adjustment
module can be rotated in a range of almost 360°. Additional detents every 90° make adjust-
ment easier. After alignment, screw the housing cover back on and secure with the locking
screw.
Do not turn beyond the end stop, otherwise damage may occur.
6.2
Operation
The TORRIX XTS indicating and adjustment module is operated in two different ways, de-
pending on whether the housing is open or closed. The actions performed by the operator
are shown on the display.
Open housing
When the housing is open, the operation is done via the 4 keys on the membrane keyboard,
which are located below the display.
Closed housing
When the housing is closed, the operation is done with a magnetic pen, the
FAFNIR magnetic
pen
, effecting through the display glass. For this purpose, 4 magnetic sensors are arranged
under the membrane keyboard in the area of the respective keys.