![fafnir TORRIX XTS Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/fafnir/torrix-xts-series/torrix-xts-series_technical-documentation-manual_3185396033.webp)
Technical Data
Page 30/
47
Measuring accuracy
Digital component
HT/HHT
Linearity better than ±1 mm or ±0.05 %, better than ±0.01 % per K
Repetition accuracy better than 0.1 mm
Resolution better than 50 µm
Measuring accuracy
Digital component
NT/LT (on request)
Linearity better than ±0.2 mm or ±0.01 %, better than ±0.001 % per K
Repetition accuracy better than 0.05 mm
Resolution
better than 10 µm
Measuring accuracy
Analogue component
Linearity better than ±0.01 %
Temperature coefficient better than 0.01% per K
Resolution better than 1 µA (15 bit)
9.2
Float
The float is an essential component of the level sensor that must be matched to the medium
in respect of density, pressure resistance and material durability.
The following floats are exchangeable and can be ordered separately. Other float types and
materials are available on request.
The density and magnet position of floats of the same type may vary slightly,
so that a readjustment may be necessary.
All floats can be used at a pressure of 1 bar (vacuum) up to the maximum
operating pressure.
Excerpt from the product range of floats:
Min. density
of medium [g/cm³]
Material
Max. operating pressure
[bar] at 20 °C
*)
Shape
[mm]
0.5
0.6
0.7
0.7
0.7
0.85
0.95
Titanium
1.4571 / 316 Ti
1.4571 / 316 Ti
C276
1.4571 / 316 Ti
1.4571 / 316 Ti
1.4571 / 316 Ti
20
20
16
10
40
20
50
Ball ø 50
Ball ø 52
Cylinder ø 53
Cylinder ø 46
Ball ø
52
Ball ø 43
Ball ø 43
*) above 50 °C the maximum operating pressure decreases
Pressure resistance is guaranteed for undamaged floats only. Even the most mi-
nor and invisible dents, which can occur if, for example, the float is dropped
from a bench onto a stone floor, are sufficient to cause a significant deteriora-
tion in pressure resistance.