10
8
9
7
5
6
4
2
3
1
!
IMPORTANT
: programming Junior is performed at first installation. Even in absence of mains power, programming is retained in the
memory. In case any time position of the limit switch brackets is changed, functions setting by mean of dip-switches or accessories
connections are modified, the gate run setting is to be re-programmed accordingly, following the same procedure.
With those installations requiring 2 Junior motors (Master and Slave), each Junior must be programmed individually.
IMPORTANT
: verify the presence of the opening and closing stops, while the opening and closing limit switch brackets must be
anchored on the gear rack in the operation positions.
IMPORTANT
: during all programming, it is necessary to wait for automatic reading of the magnetic limit switch of the Junior on the
opening and closing brackets anchored to the gear rack.
PROGRAMMING AND SELF-LEARNING OF THE GATE RUN
English
32
electro-mechanical sliding gate operator
LP
LP
LP
LP
LP
Pic. 13
=
=
1
st
operation
: unlock the release handle with the coded key and open it until it stops (beyond 90°), thus freeing the gate from the Junior
operator. Then push the gate at about halfway of its run. Reset locking condition by closing the handle. As safety measure, when the release
handle is disengaged, the electrical power supply to Elpro 64 PCB is disconnected.
2
nd
operation
:
learning the run pattern and slowdowns
.
Remove the electrical power supply to the electronic PCB by completely extracting the 230 V line fuse from its seat, found in the front,
underneath the Elpro 64 PCB. Push and hold down the P button and afterwards fit back the line fuse. After 4-5 seconds release the P button:
the LP LED will begin to flash signalling the programming phase.
At the end of the program wait until the LP LED stops flashing definitely.
Push with an impulse: the
Junior will begin to move the
gate in opening direction.
Beginning of the slowdown in
opening: push with an impulse
when the start of the slowdown
phase is desired and wait until
the limit switch is reached for
reading.
Push with an impulse: the
Junior will move the gate in
closing direction.
Beginning of the slowdown in
closing: push with an impulse
when the start of the slowdown
phase is desired and wait until
the limit switch is reached for
reading.
JUNIOR 624
CLICK
+90°
LP
LP
LP
4-5
s