Universal tank controllers
are designed to control
systems, con-
Gala-Kool Pro
wash
densing units, alarms etc. in milk cooling tanks as well as to monitor milk quality. Fur-
thermore, connected milking robots can be controlled. Any other use of the device is
permitted only with prior written permission from the manufacturer.
The controller is intended only for incorporating into machinery, display panels or
switchboxes etc. and when fitted correspond
to protection class 2 (double or rein-
ing
forced insulation) It is only allowed to be put into operation in installed state. The use
.
of the control is permitted in devices of protection class 1 and 2. The controller must
not be modified or converted in any way.
The
controller is ready for use only when the parameters have been set
universal tank
appropriately. Its use before this has been done would have no benefits and could also
damage the equipment or adversely affect the m to be temperature-controlled.
ilk
Responsibility for the faultless functioning of the connected devices lies with the plant
engineer or the installer or the service engineer who has installed and commissioned
the
.
Gala-Kool Pro
The device is fitted with a resistance temperature sensor.
The controller is not suitable for use in explosive atmospheres. Danger of explosion.
Use only outside areas subject to explosive atmospheres.
The
fulfils the EC requirements for electromagnetic compatibility
Gala-Kool Pro
(EMC) and the Low Voltage Directive (LVD).
The safety components meet the VDE regulations.
2. Safety
2.2 Intended use
These operating instructions contain important technical and safety
information. Please read carefully before installation and before any
work on or with the regulator.
Page 7
Wherever possible, keep input, output and supply leads and sensor cable physically
separate from each other and do not lay them parallel to each other.
Mains voltage cables and low-voltage cables must not be laid in one cable.
Use screened and twisted interface and sensor cables.
Earth the screening of temperature sensors unilaterally in the switchbox.
Ensure correctly wired potential equalisation.
When selecting wiring materials and installing and connecting the temperature control-
ler to the electricity supply, account must be taken of DIN VDE 0100 “Erection of power
installations with rated voltages below 1000” or the relevant national regulations (e.g.
based on IEC 60364).
2.3 Wiring, screening, earthing