9. Other Information
Page 78
The control can be programmed to delay the start of the compressor after the cool-
ing mode has been triggered, to prevent a slight freezing of milk in the tank. This
delay takes place only in case of first milking after the cleaning.
A new manual activation of the cooling start delay can be triggered only by a long
pressing of the button “COOLING”.
To cover all the different system configurations possible, the
offers
Gala-Kool Pro
a range of variants for cooling start delay.
0.
no cooling start delay
Cooling starts immediately
1.
simple cooling start delay
.
Cooling starts after a set time
2
.
periodic cooling phases
Cooling starts in the form of periodic cooling phases at set intervals before
then switching over to temperature regulation.
3.
periodic cooling phases after switch-on delay
Cooling starts after a set time, in the form of pre-set periodic cooling phases at
set intervals before then switching over to temperature regulation.
4.
according to number of milk pump impulses
Cooling starts after the set number of milk pump impulses.
5.
periodic cooling phases after a number of milk pump impulses
Cooling starts after the set number of milk pump impulses in the form of
pre-set periodic cooling phases at set intervals before then switching over to
temperature regulation.
6. Milk-volume-dependent cooling start delay
from start cooling [P50 - P 55]
Compressor starts according to the parameterized milk quantity in the tank for
the calculated running time, before switching to temperature control.
7. Milk-volume-dependent cooling start delay
from start cleaning [P50 - P 55]
Compressor starts according to the parameterized milk quantity in the tank for
the calculated running time, before switching to temperature control.
9.4 Different variants for cooling start delay
Cooling start delay s
i
set usin parameters
g
[P61 - P67].
calculated compressor
running- and break time
temperature-regulated
parameterized
milk quantity
calculated compressor
running- and break time
temperature-regulated
parameterized
milk quantity
defined phases
emperature-regulated
t
Milk pump impulses
Milk pump impulses
emperature-regulated
t
defined phases
defined tim
emperature-regulated
t
defined phases
temperature-regulated
Cooling immediately temperature-regulated
definied time
temperature-regulated