Working level
for normal daily operation
Range Default
Running times cleaning stage 0
(
rinse out)
- hidden, if [r40] = 0
n01 Water intake time
0 .. 999 sec.
0
n02 Rinse out time with water intake
0 .. 999 sec.
60
n03 Drain time
0 .. 999 sec.
60
Running times cleaning stage 1 (pre-rinse 1)
- hidden, if [r41] = 0
n10 Water intake by feed container
(displacement cleaning)
0 .. 6
0
n11 Water intake by level 1
0 .. 1
0
n12 Water intake by time
0 .. 999 sec.
70
n13
+ circulation
Additional water intake time
0 .. 999 sec.
20
n14 Main circulation time
0 .. 999 sec.
60
n15 Rinse out time
0 .. 999 sec.
0
n16 Drain time
0 .. 999 sec.
60
Running times cleaning stage 2 (pre-rinse 2)
- hidden, if [r42] = 0
n20 Water intake by feed container
(displacement cleaning)
0 .. 6
0
n21 Water intake by level 1
0 .. 1
0
n22 Water intake by time
0 .. 999 sec.
70
n23
+ circulation
Additional water intake time
0 .. 999 sec.
20
n24 Main circulation time
0 .. 999 sec.
60
n25 Rinse out time
0 .. 999 sec.
0
n26 Drain time
0 .. 999 sec.
60
Running times cleaning stage 3 (main rinse 1)
- hidden, if [r43] = 0
n30 Water intake by feed container
(displacement cleaning)
0 .. 6
0
n31 Water intake by level 1
0 .. 1
0
n32 Water intake by time
0 .. 999 sec.
70
n33
+ circulation
Additional water intake time
0 .. 999 sec.
40
n34 Main circulation time
0 .. 999 sec.
180
n35 Rinse out time
0 .. 999 sec.
0
n36 Drain time
0 .. 999 sec.
70
Switch to level
“General cleaning parameters”
See section 8.1.
n parameters
Code: B454
Applies to all “Water intake
by level 1" situations:'
0 = deactivated
1 = activated
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters
code: C567
Service parameter
s
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5
8.4 Level “General cleaning parameters” (n parameters)
8. Setting of parameters
For all „water intake by
feed container“ the
following applies:
0 = deactivated
1..6 = Number of
repetitions