![Fabdec CB2-1L120000 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/fabdec/cb2-1l120000/cb2-1l120000_installation-and-operation-manual_535775037.webp)
7 2
.5. Informative tank monitor alarms (green)
F20 Cooling time exceeded for first milking
Alarm is triggered if the temperature set in parameter [h20] is not reached within
the time set in parameter [h21].
The time starts when cooling of the first milking starts.
F22 Cooling mode switched off
At the milking time [h41-h43] entered, the cooling was not switched on.
F23 High milk temperature over period of time
Same as for faults F1 - F3.
Setting in parameter [h23 / h24]
F25 Max. milk temperature exceeded (pre-cooling malfunction)
When cooling starts, this alarm remains inactive until the milk temperature falls
below the temperature set in [h20] for the first time. It is at this point that milk
temperature monitoring starts. If the milk temperature subsequently exceeds
the temperature set in [h25], the alarm is triggered.
F27 Milk temperature too low over period of time
The alarm is triggered if the milk temperature is too low [h27] for too long
[h28]. The timer starts when the temperature falls below [h27] and stops
again when the temperature exceeds [h27]. The timer restarts each time the
temperature is exceeded.
F29 Min. milk temperature exceeded
The alarm is triggered as soon as the milk temperature falls below the tempera-
ture set in [h29].
F30 Power failure
The alarm can function only if the optional power pack is installed. Regard-
less of the operating mode, the alarm is triggered in the event of a power cut.
F31 Max. time without cooling
(starts when cooling
ends)
manually
Safety function (
! This is to prevent that after manual interruption of the cooling
mode is forgotten, to reactivate it or to start the cleaning after the milk removal.)
Timer starts as soon as cooling mode is switched off manually. The alarm is
triggered if a new cooling period or washing cycle is not started within time [h31].
F32 Max. time
cooling time not started
(starts when washing ends)
Safety function (designed to ensure that the operator does not forget to start
!
cooling mode after washing.)
Timer starts as soon as washing mode ends. The alarm is triggered if a new
cooling period or washing cycle is not started within time [h32].
F33 min. cleaning interval
Alarm is triggered, if a new cleaning does not take place within the time [h33]
F34 Incorrect time or data settings
The alarm is triggered if the date and time are lost.
F35
Alkaline drum empty
- Alerts empty detergent container
(only if optional float switch is installed and configured [h35])
F36
Acid drum empty
- Alerts empty detergent container.
(only if optional float switch is installed and configured [h36])
F38
monitoring sensor
Temperature sensor exceeded -
The alarm can function only if the optional monitoring sensor is installed and
parameters set.
The alarm is triggered as soon as the temperatures differ by value [h38].
F39
voltage too low
Battery
The alarm can function only if the optional power pack is installed. The alarm
is triggered if the battery charge is no longer sufficient.
See also section 9.21
7. Tank monitor and general fault handling
Page 37
Содержание CB2-1L120000
Страница 29: ...Page 29 ...