Working level
for normal daily operation
Don‘t add milk - temperature conditions
Range
Default
Fault
H10 Milk temperature too high for too long
F1
0 .. 50,0 °C
13,0
H11 Time limit for [H10]
0 = deactivated
0 .. 999 min.
600
H12 Milk temperature too high for too long
F2
0 .. 50,0 °C
16,0
H13 Time limit for [H12]
0 = deactivated
0 .. 999 min.
360
H14 Milk temperature too high for too long
F3
0 .. 50,0 °C
28,0
H15 Time limit for [H14]
0 = deactivated
0 .. 999 min.
300
Power failure times
H19
F6
Temperature limit for fault
0 =
F6
0 .. 50 °C
6,0
temperature-independent
H20 Max. power failure time in cooling mode
F6
0 .. 999 min.
0 = deactivated
300
Cleaning temperature monitoring
H30 Minimum cleaning temperature
F11
0 .. 50,0 °C
40,0
0 = deactivated
H31 For min. time
F12
0 .. 999 min.
2
0 = deactivated
Agitator monitoring
H40 Agitator fault in cooling mode no
of milk
-
stirring
0 = deac.
F15
0 .. 999 min.
450
H41 Timeout "No agitator"
0 = deactivated
F16
0 .. 999 min.
60
H42 Min. run time agitator
[to H41]
F16
0 .. 500 sec.
60
H parameters
Code: F94A
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters
code: C567
Service parameter
s
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5
Switch to level
“Extended tank monitor parameters”
See section 8.1.
8.8 Level “Extended tank monitor parameters” (H parameters)
8. Setting of parameters
Page 62