Settings to start cleaning (see section .3.1)
9
r27 Cleaning enable via digital input
(Default 0)
0: deactivated
1: activated
Short wash configuration Range Default
r28 Activation of short program via button
1 .. 8 0
0: deactivated
1: 1x Pre-wash 1 (Rinse 1)
2: 1x Pre-wash 2 (Rinse 2)
3: 1x After-wash (Rinse 8)
4: 1x After-wash (Rinse 9)
5: 2x Pre-wash 1 (Rinse 1)
6: 2x Pre-wash 2 (Rinse 2)
7: 2x After-wash (Rinse 8)
8: 2x After-wash (Rinse 9)
Settings for level detection (see also section .14)
9
r30 Sensitivity level input 1
(Default 0)
-10: less sensitive
+10: more sensitive
r31 Sensitivity level input 2
(Default 0)
-10: less sensitive
+10: more sensitive
r32 Timeout water intake by level
(Fault F44)
(Default 5)
Maximum time to cleaning abort: 1 .. 60 min.
r33 Level monitoring at the end of the cleaning stages
(Fault F45)
(Def 0)
.
0: deactivated
1: Level 1 monitoring only after the last cleaning stage.
activate alarm message F45 and alarm relays.
2: Level 1 monitoring after each cleaning stage.
activate alarm message F45 and alarm relays.
3: Level 2 monitoring only after the last cleaning stage.
activate alarm message F45 and alarm relays.
4: Level 2 monitoring after each cleaning stage.
activate alarm message F45 and alarm relays.
r34 Inlet pipe water detection. Max. time above the level
(Default 0)
0: deactivated
1...300 sec.
Setting of heater
r35 Heater activation
(Default 1)
0: no heater
1: only in main cleaning stage 1
2: in both main cleaning stages 1+2
3: in both main cleaning stages 1+2 and disinfection
r36 Start delay heater
(Default 0)
Range: 0 .. 120 sec.
r37 Max. running time heater
(Timeout programme step “H”)
(Default 60)
Range: 10 .. 999 min. (Fault F48)
r38 Heater protection via pressure switch
(Default )
5
0: deactivated
1.. 8 sec.: Switch off the heater after x seconds without pressure
r39 Over temperature protection heater
(Fault F49)
(Default 0)
To protect the heater (open in the
fault)
event of a
0: No protective contact
8. Setting of parameters