2
Logic A -
Logic A (automatic) is the most common setting. It automatically closes the gate de-
pending on the set pause time. This logic must be used in conjunction with the accessories: Free
Exit Sensor and Gate Timer.
Gate Status
Result of Terminal
1 activation
Result of Terminal
2 activation
Result of Terminal
4 interruption
Result of Terminal
5 interruption
Closed
Opens leaf and re-closes after pause time
No effect
Open and in
pause before
re-closing
Re-loads pause time
No effect
Re-loads pause time
Closing
Re-opens leaf
No effect
Stops motion and
reverses direction
after interruption
Opening
No effect
Reverses direction
of motion
No effect
Stopped in mid
cycle
Closes the leaf
No effect
Logic S -
Logic S (safety) is designed for higher control and accelerated levels of safety. By trig-
gering an opening device (i.e. push button, transmitter) the gate reverses directions preventing
foreseeable accidents.
Gate Status
Result of Terminal
1 activation
Result of Terminal
2 activation
Result of Terminal
4 interruption
Result of Terminal
5 interruption
Closed
Opens leaf and re-closes after pause time
No effect
Open and in
pause before
re-closing
Re-closes the leaf
No effect
Closes after 5 sec-
onds
Closing
Re-opens the leaf
No effect
Reverses direction of
motion
Opening
Re-closes the leaf
Reverses direction
of motion
No effect
Stopped in mid
cycle
Closes the leaf
No effect
Содержание Estate Swing
Страница 1: ...Featuring ...
Страница 34: ... ...