CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
50
Channel list edition 1 for EP104 version 4.08
No.
Name
Range
Factory Setting
P675
Opening via input after activation during set time, input will
not open the barrier until it has been activated for the set
time.
0.0-9.9 seconds
0.0
P680
Keep open
0 - 2
0
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal
P690
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P660 is set to open, and passes the signal on to the remote door
P696
Blocking disabled for local and remote doors. Works only
with a constant signal.
0 - 1
0
0
Disabled
1
Active
P698
Automatic closing disabled for remote door Only works if
there is a constant signal
0 - 1
0
0
Disabled
1
Active