CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
10
Channel list edition 1 for EP104 version 4.08
Safety edge
No.
Name
Range
Factory
Setting
S
C101 Safety edge acknowledgement SE.C1
0 – 1
0
0
Disabled
1
Enabled
S
C102 Function of output for external protection
0 – 4
0
0
Check disabled, open output, setting of C113, C123, C133, C143, C343, P643 is disabled.
1
Closed to GND on activation, normally open.
2
Closed to +24 VDC on activation, normally open.
3
Open on activation, normally closed to GND.
4
Open on activation, normally closed to +24 VDC.
S
C103 Function of safety edge input during test of external
safety edge unit
1 – 2
1
1
Low resistance during test
2
High resistance during test
S
C104 Connection and safety edge function
1 – 3
1
1
SE.C1 or SE.C2 can be connected to either motor 1 or motor 2.
SE.O1 or SE.O2 can be connected to either motor 1 or motor 2.
Both safety edges reverse/stop an active motor
2
SE.C1 and SE.O1 must be connected to motor 1
SE.C2 and SE.O2 must be connected to motor 2
The safety edge function is attached to the motor concerned
3
SE.C1 or SE.C2 can be connected to either motor 1 or motor 2.
SE.O1 can be connected to either motor 1 or motor 2.
Safety edges reverse/stop an active motor
SE.O2 stops active motor in both opening and closing, and is superior channel C142
C105
Halved speed or activated safety edge
(Only when using a frequency converter)
0 - 1
0
0
Disabled
1
Active
S
C111 Function for safety edge in closing direction, SE.C1
0 - 2
2
0
Disabled
1
Resistance according to set value in C115
2
Resistance between 5 kohm and 15 kohm
S
C112 Reverse/stop with activated safety edge SE.C1
1 - 2
1
1
Reverse
2
Stop
S
C113 Control of external protection connected to SE.C1
0 - 1
1
0
No check
1
Test of protection connected to SE.C1
C114
Reading resistance SE.C1
00.0-99.9 kΩ
S
C115
Resistance value for safety edge connected to SE.C1
Viewed and used only if C111 is set to 1.
1.0-9.9 kΩ
8.2