CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
22
Channel list edition 1 for EP104 version 4.08
•
DB409, Frequency Converter Board, F-channels
No.
Name
Range
Factory
Setting
F001
Communication with frequency converter
0 - 1
1
0
Communication disabled
1
Communication activated
F002
Acceleration time from closed position
from 0-100Hz
0,5 - 9,9 Seconds
1,0
F003
Acceleration time from all positions except closed
position from 0-100Hz
0,5 - 9,9 Seconds
3,0
F004
Acceleration time when P500 is set to 2 and the input
is activated, battery backup
5,0 - 12,0 Seconds
7,0
F005
Retardation time at open and close position and at
change of direction from 100-0Hz
0,5 - 9,9 Seconds
3,0
F006
Retardation time at photocell and vehicle loops from
100-0Hz
0,5 - 9,9 Seconds
1,0
F008
Low-speed frequency for opening movement
5 - 20 Hz
10
F009
Low-speed frequency for closing movement
5 - 20 Hz
10
F012
Opening frequency / Opening speed for motor 1
21 - 99 Hz
60
F013
Closing frequency / Closing speed for
motor 1
21 - 99 Hz
30
F014*
Number of degrees with low-speed frequency before
opened position for motor 1
0 - 60 Degrees
0
F015*
Number of degrees with low-speed frequency before
closed position for motor 1
0 - 60 Degrees
0
F022
Opening frequency / Opening speed for motor 2
21 - 99 Hz
60
F023
Closing frequency / Closing speed for
motor 2
21 - 99 Hz
30
F024*
Number of degrees with low-speed frequency before
opened position for motor 2
0 - 60 Degrees
0
F025*
Number of degrees with low-speed frequency before
closed position for motor 2
0 - 60 Degrees
0
F-channels are viewed only if C202=4, frequency converter