CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
25
Channel list edition 1 for EP104 version 4.08
No.
Name
Range
Factory
Setting
L120*
Placement of motor 2, viewed from the motor side
0-2
2
0
Disabled
1
Left
2
Right
L121*
Position readout, motor 2
000-360 degrees
L122*
Open position angle, motor 2
145-330 degrees
260
L123*
Closed position angle, motor 2
015-180 degrees
90
L126*
Angle for limited opening, motor 2
0-200 degrees
45
L127*
Angle for the disconnection of safety edges, load
guard and photocells from the end of the closing
movement, motor 2 in combination with C436, C341
and C448
0-30 degrees
0
L128*
Angle for the disconnection of vehicle loops from the
end of the closing movement, motor 2 in combination
with d141 or d241
0-45 degrees
0
L311
Time readout for motor 1
00.1-99.9 seconds
L312** Set time for motor 1
00.1-99.9 seconds
00.1
L321
Time readout for motor 2
00.1-99.9 seconds
L322** Set time for motor 2
00.1-99.9 seconds
00.1
* = Only displayed if L002 are set to 1.
** = Only displayed if L001 and/or L002 are set to 2 or 3.