EZTouchPLC
8 / 64
Safety Considerations
Please follow all applicable local and national codes to ensure maximum safety
of the equipment and personnel. The installation and operational environment
must be maintained per the latest revision of these codes.
You are responsible to determine the codes to be followed and to verify the
compliance of equipment, installation, and operation with the latest revision of
these codes.
It is an absolute must to follow all applicable sections of:
-The National Fire Code
-The National Electrical Code (NEC)
-The National Electrical Manufacturer's Association (NEMA) codes
Safety Guidelines
Safety is the most important element of a proper system installation. Adhering
to these safety considerations ensures the safety of yourself and others, as well
as the condition of your equipment. We recommend reviewing the following
safety guidelines:
1)
Disconnecting Main Power
The main power switch should be easily accessible to the operators and
maintenance personnel. It is important to make sure that all other
sources of power including pneumatic and hydraulic are de-energized
before starting the work on a machine or process controlled by the HMI.
2)
Safety Circuits
Most of the machines are installed with safety circuits such as limit
switches, emergency stop push buttons, and interlocks. These circuits
should always be hardwired directly to the
EZTouchPLC
unit.
These
devices must be wired in series so that when any one device
opens, the
unit is automatically de-energized. This removes power to the
machine.
These circuits should not be altered in any case, since this could
result in
serious injury or damage to the machine.
3)
Fail-Safe Operation
Our products are not fault-tolerant. They are not designed or intended
for use as online control equipment in hazardous environments requiring
fail-safe performance, such as in operation of nuclear facilities, aircraft
navigation or communication systems, air traffic control, direct life-
support machines, weapons systems, clutch control systems on presses, in
which the failure of the product could lead directly to death, personal
injury or severe physical or environmental damage. External fail-safe and/or
redundant components are required to make your control system fail-safe.
Содержание EZTouch I/O Flex
Страница 1: ...Copyright 2015 by AVG Automation All Rights Reserved EZTouchPLC ...
Страница 21: ...EZTouchPLC 21 64 Touch I O with Micro Terminal Layout ...
Страница 22: ...EZTouchPLC 22 64 Terminal Pinouts ...
Страница 23: ...EZTouchPLC 23 64 ...
Страница 26: ...EZTouchPLC 26 64 Analog I O Specifications ...
Страница 27: ...EZTouchPLC 27 64 ...
Страница 28: ...EZTouchPLC 28 64 Touch I O with Nano Terminal Layout ...
Страница 29: ...EZTouchPLC 29 64 Terminal Pinouts ...