EZTouchPLC
36 / 64
6.
Once again, a dialog box will appear. Enter "O1" as the address string. Click
OK.
7.
Click on
Instructions
>
Line
to wire “NO Contact” and “NO Coil.”
Your screen should look like this when finished:
Create a Panel Program
: Click on “Panel” and "Scr 1" to create the Panel display screen
as explained in the sample below.
1.
In the Main Menu, click on
Objects
>
Buttons
>
Buttons
. The screen below
will appear. Enter
START
for Tag Name. Click OK.
2.
A dialog box might appear requesting the memory location. Enter "S1" in the
field to the right of "Address String." The Data Type should be marked as
DISCRETE. Click OK.