Run RMC Software
To access the panel over Ethernet, you need to install and run the EZ-RMC software
on your PC. Once you run the software, you will see the following EZ-RMC dialog.
Select Parameters
Select the communication port, IP Address if
Ethernet is selected, and Polling Time. The IP
Address is the IP Address of the RMC card you
setup earlier. It is recommended to keep
polling time as high as possible.
Polling time
determines how often RMC software would
read information from the panel. A lower
polling time may impact the performance of
the panel.
Remote User
Clicking OK will prompt you to provide user name
and password, if at least one remote user has been
set up.
Please note that both user name and
passwords are case sensitive
.
If no remote users
were defined, this dialog box would not appear.
Access Password
Projects requiring an Access Password will need the
access password entered before the user
information. You must have a correct Access
Password in order to communicate with the panel.
This is project level password set during screen
design under
Setup > Panel Attribute > General Tab
.
Содержание EZTouch I/O Flex