Reference Material
This section describes:
•
•
•
Reset Modes
The TLP 350CV has four reset modes that correspond to four of the five reset modes for the IP
Link controllers. The reset modes are initiated by pressing the
Reset
,
F
,
on page 17). Use a paper clip to push through the reset button access hole.
The four reset modes are:
•
•
•
•
Use Factory Firmware
This mode is used to boot up the unit with factory-installed firmware for a single power cycle
in the event of a firmware update that failed or caused incompatibility issues with user-loaded
firmware
Activation
To start the Use Factory Firmware reset mode and replace firmware:
1.
On the touchpanel, hold down the recessed
Reset
button while applying power to the unit.
When power is restored, the Reset LED lights.
2.
Hold the
Reset
button for a further two seconds before releasing it. The touchpanel enters
factory firmware mode.
3.
Upload new firmware to the unit as desired (see
on page 40).
NOTES:
•
User-defined Web pages may not work correctly if using an earlier firmware
version.
•
Do not continue to operate the touchpanel using the factory firmware version. If
you want to use the factory default firmware, you must upload that version again
(see
on page 40).
•
If you do not want to update the firmware, or performed a mode 1 reset by
mistake, cycle power to the TLP 350CV to return to the firmware version running
prior to the reset.
Result
The unit reverts to factory-installed firmware. Event scripting does not start if the unit is powered
on in this mode. All user files and settings such as drivers, adjustments, and IP settings are
maintained.