![Extron electronics mediaport 200 Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/extron-electronics/mediaport-200/mediaport-200_user-manual_2456403152.webp)
MediaPort 200 • Remote Configuration and Control
145
Command
ASCII Command
(host to processor)
Response
(processor to host)
Additional Description
Group Masters
View group parameter
E
P
X11$
GRPM
}
X11%]
With tagged responses
(verbose modes 2 and 3):
GrpmP
X11$
*
X11%]
View group parameter
X11%
for group
X11$
.
View group members
E
O
X11$
GRPM
}
X10@
1-16
]
With tagged responses
(verbose modes 2 and 3):
GrpmO
X11$
*
X10@
1-16
]
View OID members
X10@
for group
X11$
.
View group member
values and offset for
entire group
E
V
X11$
GRPM
}
{val}
1-16
]
With tagged responses
(verbose modes 2 and 3):
GrpmV
X11$
*{val}
1-16
]
View the values and offset
for group
X11$
.
View individual group
member values and
offset
E
A
X11$
GRPM
}
{val}
]
With tagged responses
(verbose modes 2 and 3):
GrpmA
X11$
*
X11%
...
{val}
]
View the values and offset
for group
X11$
.
View soft limits
E
L
X11$
GRPM
}
X11^
*
X11&]
With tagged responses
(verbose modes 2 and 3):
GrpmL
X11$
*
...
X11^
*
X11&]
View high soft limit
X11^
and low soft limit
X11&
for
group
X11$
.
Group Master Name
Set name
E
N
X11$
*
X12^
GRPM
}
GrpmN
X11$
*
X12^]
Set name for group
X11$
.
View group master
name
E
N
X11$
GRPM
}
X12^]
With tagged responses
(verbose modes 2 and 3):
GrpmN
X11$
*
X12^]
View the name of group
X11$
.
NOTES:
X10@
X11$
= Group number: 1 - 16
X11%
= Group parameter indicator:
6
= gain,
12
= mute
X11^
= Soft limit high value (in dB).
X11&
= Soft limit low value (in dB).
X12^
=
Group master name. Maximum length is 16 characters. Invalid characters include: =
` ,
@ ‘ [ ] { } X ~ “ ; : | \ ?