![Extron electronics mediaport 200 Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/extron-electronics/mediaport-200/mediaport-200_user-manual_2456403145.webp)
MediaPort 200 • Remote Configuration and Control
138
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Ethernet Data Port
NOTES:
•
If no data is received during the timeout period, the Ethernet connection is closed.
•
With an RS-232 or USB connection, only the global timeout commands apply. A current connection
timeout command returns an error code
E13
.
Set current connection
port timeout period
13
E
0*
X6(
TC
}
Pti0*
X6(]
Set number of seconds (in
tens of seconds) before
timeout on the current IP
connection only.
X6(
=
1
through
65000
.
Default is
30
=
300
seconds = 5 minutes.
View current connection
timeout period
13
E
0TC
}
X6(]
Set global IP port
timeout
E
1*
X6(
TC
}
Pti1*
X6(]
Set number of seconds (in
tens of seconds) before
timeout on the current IP
connection only.
X6(
=
1
through
65000
.
Default is
30
=
300
seconds = 5 minutes.
View global IP port
timeout
E
1TC
}
X6(]
Serial Data Port
View parameters
E
1CP
}
[baud rate and other parameters]
Directories
NOTE:
A directory is a text string consisting of letters (a-z, A-Z), digits (0-9), hyphen or minus sign (-), plus sign
(+), or colon (:). No blanks or space characters are permitted.
Create or change a
directory
E
{path}/
...
{directory}/CJ
}
Dir
•
{path}/{directory}/
]
NOTE:
A directory does not exist until a file has been copied into the path.
Move back to root
directory
E
/CJ
}
Dir
•
/
]
Move up one directory
E
..CJ
}
Dir
•
{path}/{directory}/
]
View current directory
E
CJ
}
{path}/{directory}/
]
NOTE:
X6(
= (Ethernet only) Number of seconds (displayed tens) before timeout on IP connections
Minimum =
1
(
10
seconds), Maximum =
65000
(
650,000
seconds),
Default =
30
(
300
seconds)
Each step =
10
seconds
The response contains leading zeros. If no data is received during the timeout period, the
Ethernet connection is closed. When the unit is connected via RS-232 or USB, only global
timeout commands apply. Anything else returns an
E13
error code.