![Extron electronics DVS 304 Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/extron-electronics/dvs-304-series/dvs-304-series_user-manual_2456359064.webp)
Figure 30.
Sync to Matrix Switcher Window
NOTE:
•
The matrix switcher must be connected via a configured input on the
DVS 304 (see
Setting up the DVS to Work with a Matrix Switcher
on
•
The matrix and the DVS must to be connected to an active network at all
times to allow the products to remain synchronized. If the connection is
lost, the script needs to be restarted by either sending the SIS command
or by power cycling the DVS.
Click
Refresh Status
to update the status of the matrix switcher. Refreshing the
status returns updated information about which scaler input is tied to a particular
matrix output.
If the sync to matrix script needs to be removed or updated, click
Remove Sync
Scripts
.
•
System Settings...
— Select this to open a secondary window. This allows
changes to be made to various device settings: IP and RS-232 connections, date/
time, and passwords. Select the applicable tab, change the settings as desired, and
click
Submit
to make the changes effective.
NOTE:
Changing the IP settings may result in loss of connection to the LAN.
DVS 304 Series • SPPCP
57