Minimizing Synchronization Problems Without Using the Sync to Matrix
Feature
This section describes how to manually implement the equivalent of the Sync to Matrix
feature without using a script loaded on the DVS 304, and instead relying on a control
system.
When operating the system using a manually configured control system (for which Sync
to Matrix has not been set up), you can avoid synchronization problems that cause
unwanted image blanking or scrambling during input switches by doing the following:
NOTE:
If the Sync to Matrix feature has been previously used, first see
section on the previous page.
1.
While setting up the switcher and the DVS to work together, set the RGB delay on the
matrix switcher, so it is equal to or greater than 1.0 second.
2.
Create a tie on the matrix switcher from the desired input X to the output number that
corresponds to input 4 on the DVS 304.
3.
Immediately (within 1 second) recall the input preset on the DVS 304 associated with
the input X on the matrix switcher.
NOTE:
Input presets cannot be recalled via the front panel of the DVS 304. You
can recall them via SIS commands (see
on
the next page).
DVS 304 Series • Operation
29