ENGLISH
Displays
Display
Reason
off
Generator off
sTaRT
The start-up phase is in progress
pelleT loaDinG
Continuous pellet loading is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The preparation phase is in progress
WoRk
The normal work phase is in progress
MoDulaTion
The generator is working at minimum
final cleaninG
The final cleaning is in progress
sTanD by
Generator off waiting for re-ignition due to the external thermostat.
coolinG
sTanD by
A new ignition is attempted when the generator has just been switched off. When the generator switches off, you must
wait for the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when
these operations have been performed.
black ouT
sTanD by
The generator is cooling after a power cut.
Once cooling is completed, it will re-start automatically
auTo bloW
The automatic blow is active
close
HoppeR-sToVe DooR
This indication means that you have 60 seconds to close the hatch/door and the pellet lid.
After 60 seconds have passed, the stove will enter “
DEPR ALARM
” during the ignition phase, while during normal
operation, the stove will enter "
COOLING STAND BY
" and then restart automatically when the conditions are met (cold
stove, etc.). This message is also displayed in the case of insufficient draught.
alaRMs
Display
eXplanaTion
soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm
The alarm can only be reset if the fumes motor has stopped and 15
minutes have passed since the alarm was displayed, by pressing key 1
for 3 seconds.
fuMes MoToR
faulT
Fumes motor fault
Contact after-sales centre
fuMes pRobe
Fumes probe fault.
Contact after-sales centre
HoT fuMes
High fumes temperature
Check pellet loading (see "Easy setup"); if the problem is not solved,
contact a service centre.
no
iGniTion
The pellet hopper is empty.
Pellet feed calibration inadequate.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
Check the procedures described in the “Ignition” chapter.
Check bulb thermostats (see chapter on Resetting)
no flaMe
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
Check bulb thermostats (see chapter on Resetting)
DepR alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
no
iGniTion - black ouT
No power during the ignition
phase.
Turn the stove off using key 1 and repeat the procedure
described in the "Ignition" chapter.
Other reset operations should be performed by
an authorised technician.
coMManD auGeR
alaRM
Abnormal pellet loading.
Contact after-sales centre