ENGLISH
hOT AiR DUCTiNg
The pipe used for ducting the hot air must have an internal diameter of 80 mm and it must also be insulated or at least be protected against
heat dispersion.
Features:
rear or lateral outlet
diameter of air ducting outlet: 80 mm
maximum recommended air ducting length 8 m
possibility to thermostat the ducting
3 possible settings: OFF, COMFORT, AUTO.
ADDiTiONAl TheRmOSTAT TO CONTROl The DUCT mOTOR
For models with duct motor, it is also possible to thermostat the motor itself. The connection to an external thermostat will allow for the
duct motor to be controlled regardless of stove operation.
At this point, simply set the desired temperature on the thermostat; the thermostat will command
the operation of the second motor:
when the temperature has not been reached (contact closed) the second motor will follow the
operation of the stove.
when the temperature has been reached (contact open), the motor will switch off.
The duct thermostat terminal features a standard bridge.
See drawing to the side.
SPACeRS
There are 2 spacers located at the back of the machine which determine the minimum distance from any support behind the stove.
The spacers must not be removed.
Please note: direct the room probe downwards or towards the outside of the stove.