settInGs

• 

date-tIme

• 

lanGuaGe

• 

deGrees

 

See chapter: firSt ignition SettingS

DISPLAY

This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. If set to OFF, the display backlighting is set 

to maximum brightness and turns off after a 60 second delay.

The backlighting can be turned on again by pressing any key or if the stove is in the alarm condition.

CONTROLS PROCEDURE

 

Š

Press key 6.

 

Š

Press key 3 until 

SETTINGS

 appears and confirm by pressing key 6.

 

Š

Keep pressing key 3 until 

DISPLAY

 appears and confirm by pressing key 6.

 

Š

Use keys 4-5 to set the desired intensity.

 

Š

Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.

STAND BY

The 

STAND BY

 function, if enabled, is used when stove switch-off is to be controlled by means of an additional thermostat

CONTROLS PROCEDURE

 

Š

Press key 6.

 

Š

Press key 3 until 

SETTINGS

 appears and confirm by pressing key 6.

 

Š

Keep pressing key 3 until 

STAND BY

 appears and confirm by pressing key 6.

 

Š

Use keys 4-5 to enable (

ON

) / disable (

OFF

).

 

Š

Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.

J

FOR CORRECT OPERATION, THE SET THERMOSTAT MUST BE SET TO LOW-TA.

> SEE THE ADDITIONAL THERMOSTAT INSTALLATION CHAPTER

stand By funCtIon set to on

If the 

STAND BY

 function is enabled (ON) and the room temperature exceeds the 

SET THERMOSTAT

 + 

DELTA-T OFF

 value, then the stove 

switches off after a preset factory delay, and 

STAND BY

 will be displayed on the screen.

When the room temperature is lower than the 

SET THERMOSTAT

 - 

DELTA-T ON

 and after a possible cooling time, the stove switches back on.

stand By funCtIon set to off (faCtory settInG)

When the 

STAND BY

 function is not enabled (OFF), if the stove exceeds the set room temperature, it will switch to the minimum power level, 

modulating and displaying 

MODULATION

 on the screen. When the room temperature is lower than the 

SET THERMOSTAT

 the stove will 

restart at the set power and 

WORK

 will be displayed on the screen.

operatIon WIth addItIonal thermostat (optIonal) 

stand By funCtIon set to off

 (FACTORY SETTING)

When the 

STAND BY

 function is not activated (OFF), if the stove exceeds the room temperature set on the additional thermostat (open 

contact), it switches to the minimum power level and displays 

MODULATION

 on the screen. When the room temperature is lower than the 

set value on the additional thermostat (closed contact), the stove will resume operation at the set power, and 

WORK

 will be displayed on the 

screen.

stand By funCtIon set to on

If the 

STAND BY

 function is activated (ON), when the room temperature set on the additional thermostat is reached (open contact), the stove 

will switch off after a pre-set default delay period, and 

STAND BY

 will be displayed on the screen.

When the room temperature is less than the set temperature on the additional thermostat (closed contact), and after a certain cooling time, 

the stove ignites again.

Содержание GABRIELLA PLUS

Страница 1: ...MADE IN ITALY design production GABRIELLA PLUS 004280494 Rev 000 UK pellet stoves USER MANUAL...

Страница 2: ...2 ENGLISH APPLY TECHNICAL DATA LABEL...

Страница 3: ...ENABLING DISABLING THE CHRONO 24 SETTINGS 26 Display 26 STAND BY 26 OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL 26 ADDITIONAL THERMOSTAT 27 ADDITIONAL THERMOSTAT INSTALLATION 27 DELTA T 27 FIRST LOA...

Страница 4: ...retirer les pi ces en fa ence pierre naturelle ou m tal de la partie sup rieur du produit In den ersten Betriebsstunden k nnen durch den normalen Prozess des Temperatureinlaufs D mpfe und Ger che ent...

Страница 5: ...ance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be h...

Страница 6: ...IF IT IS DISCONNECTED FROMTHE MAINS It is advised to position the power supply cable so that it does not come into contact with hot parts ofthe appliance The power supply plug must be accessible afte...

Страница 7: ...clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICA...

Страница 8: ...pace heating energy efficiency Space heating emissions at nominal heat output Space heating emissions at minimum heat output Nominal heat output Minimum heat output indicative Useful efficiency at nom...

Страница 9: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can als...

Страница 10: ...always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be prov...

Страница 11: ...tension and rear closure 5 Install rear cover 6 Insert upper discharge UPPER FUMES OUTLET ASSEMBLY FOLLOW THE ASSEMBLY INSTRUCTIONS CAREFULLY ALWAYS FOLLOW THE ASSEMBLY INSTRUCTIONS IN COMPLETE SAFETY...

Страница 12: ...This means that it is ideal for passive houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combust...

Страница 13: ...haust Fuse C Access to combustion chamber 230 V power supply D Lateral ducting K Serial input E Room probe Additional thermostat input F Room air outlet Ducting thermostat input G Display L Rear ducti...

Страница 14: ...rmostat will allow for the duct motor to be controlled regardless of stove operation At this point simply set the desired temperature on the thermostat the thermostat will command the operation of the...

Страница 15: ...CLOSE HOPPER STOVE DOOR This indication means that you have 60 seconds to close the hatch door and the pellet lid After the 60 seconds during ignition the stove will go into DEPR ALARM mode while dur...

Страница 16: ...OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND MAY INVALIDATE THE WARRANTY AND RELIEVE THE MANUFACTURER OF ALL RESPONSIBILITY PELLET HOPPER During stove operation the pellet hopper lid mus...

Страница 17: ...ck keyboard 3 On off stove hold for 3 seconds 9 Degrees Celsius Fahrenheit 4 Set power 10 Press the button once to enable or disable the chrono 5 Set switch off delay The button allows to set the swit...

Страница 18: ...gnal receiver Handle the remote control with care When it is not being used place it on the special base supplied The remote control must not be left in a place where it is exposed to direct sunlight...

Страница 19: ...ed contact the contact of the external additional thermostat is closed Open contact the contact of the external additional thermostat is open Icon visible only if SET THERMOSTAT is set to LOW TA WI FI...

Страница 20: ...nded to Ventilate the room well If present remove any majolica or natural stone parts from the top part of the product Activate the product at the maximum power and temperature Avoid remaining in the...

Страница 21: ...Select the language using keys 4 or 5 Press key 6 to confirm and key 1 to scroll back through the menus until the initial page DEGREES This menu allows you to set the unit of measurement for the temp...

Страница 22: ...ed modulation LOW TA HOT If the Set Thermostat is LOW TA set under the 7 threshold temperature checking is entrusted to the additional thermostat contact thus bypassing the on board temperature probe...

Страница 23: ...E RANGE SECOND INCREASE RANGE IF THE FIRST IS INSUFFICIENT THIRD INCREASE RANGE IF THE FIRST TWO ARE INSUFFICIENT Controls procedure Press key 6 Press key 3 until EASY SETUP appears and confirm by pre...

Страница 24: ...T Set thermostat PRG3 POWER PRG3 1 5 Set power PRG3 PRG4 START PRG4 OFF 00 00 Ignition time PRG4 STOP PRG4 OFF 00 00 Switch off time PRG4 MONDAY SUNDAY On off Enable disable days PRG4 SET PRG4 LOW TA...

Страница 25: ...0 23 00 08 00 16 30 t 22 18 2 1 25 ENGLISH Time slot 1 start 02 00 stop 23 00 power 3 SET THERMOSTAT 22 C Time slot 2 start 08 00 stop 16 30 power 1 SET THERMOSTAT 18 C stove operation TIME SLOT SET P...

Страница 26: ...HERMOSTAT DELTA T OFF value then the stove switches off after a preset factory delay and STAND BY will be displayed on the screen When the room temperature is lower than the SET THERMOSTAT DELTA T ON...

Страница 27: ...round equal to 1 50 m Stove operation with the external thermostat connected in the TA terminal may differ depending on whether or not the STAND BY function is enabled ADDITIONAL THERMOSTAT INSTALLATI...

Страница 28: ...function allows you to lock the display keys similar to mobile phones With the function active each time a key is pressed the message KEYS LOCKED will appear To lock the keypad press keys 1 and 5 simu...

Страница 29: ...ions may lead to damage to the generator surfaces and invalidate the warranty CLEANING THE CERAMIC GLASS Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be c...

Страница 30: ...ush it towards the hearth wall C Reposition the ash conveyor making sure that it rests on the burn pot correctly and not on another surface of the combustion chamber Keep the burn pot clean using the...

Страница 31: ...ER TOP PART Remove the deflector and eliminate any ash that may have deposited in the top part of the heat exchanger using the pipe cleaner supplied Pay attention to any ash that may have deposited on...

Страница 32: ...ance must be performed at least once a year Giventhatthegeneratorusespelletsassolidfuel itrequiresannualroutinemaintenance whichmustbeperformedbyaQualifiedtechnician using only original spare parts Fa...

Страница 33: ...1 2 3 4 5 33 ENGLISH HEAT EXCHANGER...

Страница 34: ...s B Gaskets pellet hopper inspections ash drawer and door replace and apply silicone where indicated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complet...

Страница 35: ...ts B Gaskets pellet hopper inspections ash drawer and door replace and apply silicone where indicated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper comple...

Страница 36: ...ndicates the presence of an alarm On indicates the presence of an alarm The alarm can only be reset if the fumes motor has stopped and 15 minutes have passed since the alarm was displayed by pressing...

Страница 37: ...kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local...

Страница 38: ...38 ENGLISH...

Страница 39: ...39 ENGLISH...

Страница 40: ...39 0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufac...

Отзывы: