32
ENGLISH
IF THE POWER CORD IS DAMAGED, IT MUST BE REPLACED BY THE SERVICE CENTRE OR BY A SIMILARLY QUALIFIED
PERSON, SO AS TO AVOID ALL RISkS.
PARTS/FREQUENCY
EVERY DAY
EVERY 7 DAYS
EVERY 30 DAYS
EVERY YEAR
BURN POT AND COMBUSTION CHAMBER (USER)
X
HEAT EXCHANGER - TOP PART (USER)
X
EXTRACTABLE ASH DRAWER 1 (USER)
X
REMOVABLE ASH DRAWER 2 (USER)
X
HEAT EXCHANGER (TECHNICIAN)
X
T-SHAPED FITTING / SMOKE DUCT (TECHNICIAN)
X
One day means an average use of 8h at the rated power.
How often the ash drawer is emptied depends on a number of factors: the type of pellets, the stove output, the use of the stove and the
type of installation.
J
A CLEAN BURN POT GUARANTEES CORRECT OPERATION!
BY kEEPING THE BURN POT AND ITS HOLES CONSTANTLY CLEAN AND FREE OF
COMBUSTION RESIDUE, EXCELLENT COMBUSTION IS GUARANTEED OVER TIME,
THUS PREVENTING ANY GENERATOR MALFUNCTIONS THAT MAY REQUIRE
TECHNICAL ASSISTANCE.
THE “EASY SETUP” FUNCTION IN THE USER MENU CAN BE USED TO ADAPT
COMBUSTION ON THE BASES OF THE NEEDS DESCRIBED.
THE SEALS OF THE PELLET HOPPER, BURN POT AND FIRE DOOR ENSURE THE CORRECT OPERATION OF THE STOVE.
THESE NEED TO BE PERIODICALLY CHECkED BY THE USER. IF THEY ARE WORN OR DAMAGED, REPLACE THEM
IMMEDIATELY.
THESE OPERATIONS MUST BE CARRIED OUT BY A QUALIFIED TECHNICIAN.
ROUTINE MAINTENANCE PERFORMED BY QUALIFIED TECHNICIANS
Routine maintenance must be performed at least once a year.
Given that the generator uses pellets as solid fuel, it requires annual routine maintenance, which must be performed by a
Qualified technician,
using only original spare parts.
Failure to comply may jeopardise safety of the appliance and invalidate the warranty conditions.
By observing the cleaning schedule reserved to the user described in the use and maintenance manual, the generator will be guaranteed
correct combustion over time, thus preventing any faults and/or malfunctions which may require subsequent technical assistance. Requests
for routine maintenance are not covered by the warranty.
GASkETS: PELLET HOPPER LID, DOOR, ASH DRAWER AND BURN POT
The gaskets ensure the proper sealing of the stove and therefore its proper operation.
They must be periodically checked and immediately replaced if worn or damaged.
These operations must be carried out by a qualified technician.
CONNECTION TO THE FLUE
Annually, or in any case each time the flue pipe needs to be vacuumed and cleaned. If there are horizontal sections, the residue must be
removed to prevent it from obstructing the flow of fumes.
SHUT-DOWN (END OF SEASON)
At the end of each season, before turning the stove off, it is advisable to empty the pellet hopper out completely and vacuum any pellet and
dust residues. It is also advisable to disconnect the generator from the electrical power supply and, for greater safety especially in the presence
of children, remove the power cord. Routine maintenance must be performed at least once a year.