27
ENGLISH
FIRST LOAD
This function allows the auger to be filled, thus facilitating first stove ignition phases, or in the event the pellet hopper is empty. With the
stove cold and "OFF", make sure the pellets have been introduced inside the hopper and activate the
FIRST LOAD
function, confirming by
pressing OK.
To stop the continuous loading, simply press 1 for 3 seconds.
CONTROLS PROCEDURE
Press key 6.
press key 3 until
SETTINGS
appears and confirm by pressing key 6.
Keep pressing key 3 until
FIRST LOAD
appears and confirm by pressing key 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to confirm and exit the menu.
J
for CorreCt operatIon, set the
SET
THERMOSTAT
dedICated to the room
temperature to
LOW-TA
addItIonal thermostat
n.B. : InstallatIon must Be performed By an authorIsed teChnICIan
It is possible to control the temperature of a room adjacent to the room where the stove is positioned; simply connect a thermostat following
the procedure described in the following section (it is advisable to place the optional mechanical thermostat at a height off the ground equal
to 1.50 m). Stove operation with the external thermostat connected in the TA terminal may differ depending on whether or not the STAND
BY function is enabled.
addItIonal thermostat InstallatIon
Switch the appliance off using the master switch positioned at
the back of the stove.
Remove the plug from the socket.
Connect the two cables of the thermostat (clean contact - no
230 V!) on the terminal (TA) behind the machine.
RESET
Allows the user to reset all editable values to the default values.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until
SETTINGS
appears and confirm by pressing key 6.
Press key 3 until
RESET
appears and confirm by pressing key 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to confirm and exit the menu.
delta-t
This function allows the hysteresis thresholds to be set for stove ignition (DELTA-T ON) and switch-off (DELTA-T OFF), used as a room
temperature adjustment interval if not managed by an external thermostat
.
The possible values of
DELTA-T
vary between:
0.5 - 5°C
CONTROLS PROCEDURE
Press key 6.
Press 3 until
SETTINGS
appears and confirm by pressing 6
Press 3 until
DELTA-T
appears and confirm by pressing 6.
Use keys 4-5 to set the desired value.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.