41
40
EN
EN
•
WARNING
y
The floodlight is designed for permanent
connection to an el. power source, e.g. termi-
nal box. For safety reasons, according to the
current standards EN 50110-1, IEC 60050-195 and
EN 50110-2 and EN 61140+A1 the connection
may only be performed by a person with appro-
priate professional electrical qualifications ( i.e.
"person skilled in electrical installations"). If
you do not have such qualifications, have the
appliance connected by a professional. The
manufacturer is not responsible for damages or
injuries arising from the unprofessional conne-
ction of the floodlight to an el. power source or
for damages resulting from a connection of the
floodlight to an el. power source not protected
against water because the IP protection mar-
king does not apply to the connection of the
floodlight to an el. power source.
CONNECTION
•
WARNING
y
The floodlight can be connected to a voltage
in the range specified in the chapter with the
technical specifications. Prior to connecting
the floodlight, check that the above speci-
fied voltage is in the grid.
y
The floodlight must be connected to a grid
fitted with a residual current device (RSD)
with a breaking current of 30 mA.
y
Prior to connecting the floodlight, make sure that
all relevant el. devices are not under voltage.
y
A three conductor electric cable must be used for the
connection.
y
The conductors must be connected as follows:
- Yellow-green wire must be connected to the termi-
nal with the „ground“ symbol.
- Blue wire to the terminal marked with the N (zero) symbol.
- Brown wire to the terminal marked with the
L (phase) symbol.
y
When connecting the power cable to the conductors
on the floodlight, the connected conductors must be
of the same colour.
•
ATTENTION
y
The terminal box or any other supply line for the
connection of the floodlight must be permanently
protected against the entry of water. The IP pro-
tection level of the floodlight does not apply to the
floodlight‘s connection to the power source when the
same level of protection is not provided!
y
Do not locate the floodlight on a flammable surface.
The floodlight must not be used in an environment
where there is a risk of fire or explosion.
y
Always use the floodlight with an undamaged
protective front cover that prevents damage to
the LED diodes and their exposure to humidity/
water and dust. In the event that the flood-
light is damaged, immediately turn off the
power source, disconnect it and replace it with
an undamaged unit.
MOUNTING THE FLOODLIGHT
y
Mount the floodlight at a height of 1-3 m above the
ground. The direct distance of the floodlight from the
illuminated object should be at least 0.5 m (Fig. 2).
When the floodlight is mounted in a corner then it
must be at least 20 cm away from the ceiling (Fig. 3).
0.5 m
Min.
1
m
Max.
3
m
Fig. 2
Angle of light emission
into space
120°
120°
120°
Highlighting light source
×
×
×
Dimmability of the light
source
×
×
×
Number of switch cycles to
malfunction
≥ 15000
×
≥ 15000
×
≥ 15000
×
For outdoor use
IP 65
IP 65
IP 65
Dimensions of the light
source
121 × 128 × 36 mm 185 × 182 × 38 mm 230 × 225 × 52 mm
Mercury content in the
light source
0.0 mg
0.0 mg
0.0 mg
Table 2
ENERGY LABEL OF THE FLOODLIGHTS
A
++
A
+
A
B
C
D
E
874/2012
L
E
D
This floodlight
contains built-in
LED lamps.
The lamps cannot be changed
in the floodlight.
Item No.
43221, 43223,
43232
1)
2)
Fig. 1
III. Connection and
installation of the floodlight
•
ATTENTION
y
Carefully read the entire user‘s manual before first use
and keep it with the product so that the user can learn
about it. If you lend or sell the product to somebody,
include this user‘s manual with it. Prevent this user‘s
manual from being damaged. The manufacturer takes no
responsibility for damages or injuries arising from use of
the device that is in contradiction to this user‘s manual.
Acquaint yourself with all the control elements and parts
of the floodlight before using it. Check that all parts are
firmly attached before use, also check that no part of the
floodlight is damaged, namely the protective front cover
and the insulation on the power cord. A degraded power
cord is also considered to constitute damage. Do not use
a floodlight with damaged parts and have it repaired at
an authorised service centre for the Extol® brand.
1)
This lighting
device contains
a built-in LED
light source.
2)
The light source
in this lighting
device cannot be