Functional characteristics
TIG welding
48
Item No.: 099-004877-EWM01
5.3.10
TIG shielding gas setting
5.3.10.1
Gas test
Operating
element
Action Result
x x
Press the "Select welding parameter" button until the "activArc" LED
flashes.
5 sec.
Press the "Select welding parameter" button and hold for approx. 5 sec.
The gas pre-flow time LED (TIG)
sec
will come on,
shielding gas flows for approx. 20 sec.
5.3.11
TIG welding torch (operating variants)
There is the option of connecting various operating and display elements to the welding torch. The
functions of the torch triggers (TT) and the operating elements can be adjusted individually using different
modes (see chapter “Setting the torch mode and up/down speed”).
Explanation of symbols Operating elements:
Symbol Description
BRT 1
Press torch trigger
BRT 1
Tap torch trigger
BRT 2
Tap and press torch trigger
For more detailed torch descriptions, see chapter "Setting the torch mode and up/down speed".