Functional characteristics
TIG welding
56
Item No.: 099-004877-EWM01
5.3.13
Setting the first increment
Figure 5-14
This function is only available when using up/down torches in modes 4 and 14.
Operating
element
Action Result
Display
Switch off the welding machine
-
Press and hold key button
-
Switch on welding machine
Select Torch mode menu item "trd"
The parameter that can be changed and the associated value blink alternately in the display.
1 x
Hold until menu item "tod" (torch mode) is displayed
Set torch mode
(mode 4, with tapping mode,
mode 14, no tapping mode)
1 x
Select increment
Set increment
Setting range: 1 A to 20 A
Select Torch mode menu item "trd" (deselection)
Select Configuration menu item "Eit" (deselection)
1 x
Deselection "Eit" (Exit)
Welding machine is re-initialised