Functional characteristics
Key switch
58
Item No.: 099-004877-EWM01
5.4.2.2
Hotstart time
Operating
element
Action Result
Displays
Select hotstart time welding parameter
Press until hotstart time light
sec
comes on
Set hotstart time
5.4.3
Arcforcing
Shortly before the electrode threatens to stick, the arcforcing device sets an increased current designed
to prevent the electrode sticking.
Operating
element
Action Result
Displays
1 x
Select arcforcing welding parameter
The
signal light lights up in red
Set arcforcing
-40
= low current increase > soft arc
0
= default setting
+40
= high current increase > aggressive arc
5.4.4
Antistick
Anti-stick prevents the electrode from annealing.
If the electrode sticks in spite of the Arcforce device, the
machine automatically switches over to the minimum
current within about 1 second to prevent the electrode
from overheating. Check the welding current setting
and correct according to the welding task!
5.5
Key switch
To protect against unauthorised or unintentional adjustment of the welding parameters on the machine,
the control input can be locked with the aid of a key switch.
Key position 1 =
All parameters can be set
Key position 0 =
The following operating elements/functions cannot be changed:
• "Welding process" button
• "Welding current polarity" button
• Parameter values in the function sequence can be displayed but not
changed